Evidence at a glance
- Evidence level
- Multiple levels: standards, established thermal principles, growing field evidence and project translation.
- Application type
- Evidence-based recommendation and project-specific comfort strategy.
- Published or updated
- Updated 29 July 2026
- What this did not prove
- No universal thermostat setting can guarantee comfort, sleep, health or energy performance.
Thermal comfort in hot-humid residences
Thermal comfort varies between people, rooms and moments. A project target is not a universal guarantee of comfort.
Beyond cooling capacity
The thermostat can be satisfied while the person is not.
A chair beside sun-heated glass can feel hot when the room sensor reports an acceptable temperature. A bedroom can feel clammy when the air is cool but the moisture remains high. A powerful AC unit can create noise and a cold jet at the bed while leaving the room uneven.
Comfort has to be designed through the envelope, shade, room geometry, air movement, moisture control, zoning and controls before it is treated as an equipment-size problem.
One condition, several inputs
Each variable changes the meaning of the others.
Air temperature
Important, but insufficient on its own. It does not describe hot surfaces, solar exposure, humidity or the air moving across the body.
Mean radiant temperature
Roofs, glazing, walls, floors and direct sun exchange heat with the occupant. Reducing radiant load can improve comfort without lowering the thermostat.
Humidity and dew point
High moisture reduces evaporative cooling and raises condensation and mould risk when cold surfaces are introduced. A clammy room often needs latent control, not simply more sensible cooling.
Air movement
Fans and local air movement can extend comfort in warm conditions. Distribution, noise, control and the occupied position determine whether the result feels useful or drafty.
Activity, clothing and bedding
Cooking, working, exercising, bathing, resting and sleeping create different loads. Bedding can change the night-time condition more than a small thermostat adjustment.
Expectation and control
People tolerate and understand conditions differently when they can make a clear local adjustment. Control should be real, legible and bounded by safe operating logic.
Diagnose before cooling
Resolve the dominant load in the right order.
Layer 01, Radiant load
Question
Is the person hot because of sun, roof, glazing or warm surfaces?
Project response
External shade, roof and ceiling strategy, glazing control, protected terraces and reduced reflected hardscape gain.
Layer 02, Adaptive opportunity
Question
Can a better condition be created through shade, air movement, position or a suitable opening?
Project response
Ceiling fans, local fans, insect-screened openings, alternative seating and understandable local control.
Layer 03, Moisture load
Question
Is the room muggy rather than simply hot?
Project response
Latent-capable cooling, dehumidification, controlled outdoor air and condensation-aware operation.
Layer 04, Air movement
Question
Would more air speed help without creating noise or unwanted draft?
Project response
Map fan distribution at the bed, sofa, desk and circulation zone rather than approving the fan by catalogue diameter alone.
Layer 05, Sensible cooling
Question
Is the operative condition still too warm after load reduction and useful air movement?
Project response
Use zoned cooling coordinated with humidity and fan logic rather than deep-cooling the whole residence.
Layer 06, Personal variance
Question
Do the owner, partner, children, guests and staff need different modes?
Project response
Provide room-level control and a small number of understandable comfort modes instead of one universal setpoint.
Layer 07, Sleep exception
Question
Is this a bedroom during the sleep period?
Project response
Prioritise low noise, stable humidity, low radiant load, gentle airflow, bedding assumptions and an easy bedside override.
Mixed mode without contradiction
A residence needs rules for when each system takes over.
Open comfort mode
Uses shade, useful outdoor air and fans when outdoor humidity, rain, particles, insects and noise are acceptable.
Fan-first mode
Uses local air movement before a lower cooling setpoint when humidity and room use allow it.
Closed comfort mode
Uses zoned cooling, moisture control and controlled outdoor air for protected rooms or unfavourable outdoor conditions.
Night bedroom mode
Uses quieter, more stable operation, gentle air distribution and a small number of local controls.
Arrival mode
Prepares humidity and temperature in the right sequence before the owner or guest enters, rather than relying on a last-minute deep-cool.
Absence mode
Protects the building and contents without operating the whole residence as if it were occupied.
Mixed mode fails when several systems act against one another. Windows can be open during high outdoor dew point. A fan can run under an excessively cold jet. The thermostat can be satisfied while the room remains humid. The project must define transitions and failure states rather than leaving them to habit.
Climate and household
The same villa can need different logic by micro-location, season and use.
Coastal, inland and upland locations do not carry the same radiant, humidity, wind, noise and corrosion conditions. An owner-occupied residence, a family estate and a serviced villa also behave differently.
The design has to consider:
- west and roof exposure;
- hardscape and pool reflection;
- high ceiling stratification;
- rainy-season latent load;
- salt and corrosion where relevant;
- owner, guest and staff expectations;
- occupied, hosting and vacant modes;
- power interruption and restart;
- local service and spare parts;
- AC noise and fan noise at night.
Comfort in the occupied position
Capacity alone does not prove the room condition.
Verification sequence
- Record the room use, occupancy, clothing and bedding assumptions.
- Review solar and radiant load at the actual occupied positions.
- Map shade, openings, fans, cooling and moisture-control roles.
- Confirm operating modes and local overrides.
- Test critical rooms or positions through mock-up or staged operation.
- Measure temperature, humidity and air movement where the question requires it.
- Check noise, draft and condensation risk during real operation.
- Tune the system before opening and review overrides after occupation.
Possible project tests
- late-afternoon solar-patch test;
- bedroom night test comparing quiet cooling, fan and latent-control options;
- rainy-season vacancy test;
- pre-arrival sequence test;
- mixed-mode switchover test;
- seating and bed-position air-movement map.
Evidence outputs
- thermal and radiant risk map;
- operating-mode register;
- fan and air-distribution test;
- temperature, RH and dew-point trends;
- control and override log;
- noise and draft observations;
- commissioning and retuning record;
- Building Passport entries.
Limits
No one temperature is comfortable for every person or every room.
Standards and field studies provide methods, ranges and decision tools. They do not establish a single perfect setpoint for all households. A fan is not a universal replacement for moisture control. Lower temperature does not automatically mean better sleep. A smart thermostat does not see every radiant, humidity or airflow condition.
A project can verify environmental conditions and user control under stated conditions. It cannot guarantee comfort at all times or for every occupant.
Claims boundary
Universal comfort, one ideal Bali temperature, universally sufficient fans, sleep outcomes, thermostat-only proof and automated personal optimisation are outside the evidence.
Related Study Note
Thermal comfort is not one thermostat number
Related theme
Indoor environment and moisture
Related protocol
Protected Bedroom Performance Protocol
Before equipment selection
Design the condition before choosing the capacity.
DALLEAU Atelier connects the owner’s comfort priorities to shade, envelope, air movement, moisture control, zoning, controls, mock-ups and commissioning.
Sources
The source finding and DALLEAU's residential interpretation are kept separate. Links open the original publisher or authority record.
- Thermal Environmental Conditions for Human Occupancy
Authoritative guidance. Thermal comfort as an interaction between temperature, radiation, humidity, air speed, activity and clothing. Limit: One thermostat setting that guarantees comfort for every person.
- Ergonomics of the thermal environment — PMV, PPD and local thermal comfort criteria
Authoritative guidance. Analytical evaluation of general and local thermal comfort in moderate environments. Limit: A universal residential setpoint or direct transfer without project context.
- Occupant's preferred indoor air speed in hot-humid climate and its influence on thermal comfort
Growing evidence. Controlled evidence that preferred air speed varies with thermal and humidity conditions. Limit: A universal air-speed target for every resident, room or activity.